Volume: 500 l
Weight: 103 kg
Outside diameter of the tank: 700 mm
Height: 1920 mm
Max. water pressure in the tank: 0,6 MPa
Max. temperature of heating water in the tank: 80 °C
Insulation thickness: 50 mm
Maximum number x power of heating unit TJ 6/4": 2 x 9 kW
Storage tank UKV has several different areas of use.
UKV can be used with external control of the heating system. The heat pump then charges UKV with floating or fixed condensing. The external control function controls the heat distribution from UKV to the consumer. If the flow to the heating system can be throttled with radiator thermostats for example, install a UKV as an intermediate tank. This ensures a secure flow for the heat pump.
Storage tank UKV also allows agreater flow to the heating system than across the heat pump. In some installations, so - called heat spikes occur as aresult of movements during temperature changes. To eliminate temporary temperature changes, and the reby prevent heat spikes, install a UKV after the heating installation.
Storage tank UKV can also be used to increase the system volume and prevent malfunctions
Storage tank UKV is equipped with two hinges. If you want to change the side on which the plun ger pipe is located, the hinges can be reversed. Prior to commissioning, we recommend that you run the heating circuit and any impurities that are trapped in the filter clean, then the system is fully operational.